The Baseline Difference

Explore the “why” behind the strategy and the benefits of Baseline’s services

Strategy Centered Around Service

Hover over a category
to learn more

Click a category
to learn more

Remote Monitoring
Technology

24/7 Rapid
Response

Custom Power
Solutions

Baseline’s remote monitoring service ensures that even when not on location, our personnel always have eyes on to ensure flawless 24/7 performance. If there’s a potential issue, we are the first to know and the first to react.

About Us

You need power available 24/7. Our highly trained generator technicians work around the clock to ensure maximized runtime.

About Us

Out here, every project is custom. An ESP powered by a 350 kW generator fueled by propane. A field of production equipment receiving electricity from overhead lines that are fed by a 10 MW microgrid fueled by pipeline gas. And everything in between.

About Us

Featured Case Study

Switching From Diesel to Natural Gas

Oil and Gas Services Firm Realizes Environmental Benefits and Cost Savings With Switch to Natural Gas-Fired Power Generation

View Case Study

Featured Case Study

Permian Operator Takes Electric Power Supply into Own Hands

Baseline Plays Major Role in Building Reliable Microgrid with Stunningly Low Emissions Profile Using Field Gas in New Mexico

View Case Study

Featured Case Study

Mid-Con Operator Goes Off-Grid, Gets Back to Business

Kansas Independent Oil and Gas Producer Utilizes Wellhead Gas, Natural Gas Generators From Baseline, To Provide Boost During Downturn

View Case Study

Product Showcase

NG 400

The robust industrial 22L turbo charged engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 350 KW
  • Engine Prime Rating HP: 580 HP
  • Prime Power AMP Rating: 526 A
  • Fuel Usage (Field Gas): 56 MCF/DAY AT 50%, 79 MCF/DAY AT 75%
  • Fuel Usage (Propane): 538 GAL/DAY AT 50%, 799 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 250

The robust industrial 14L turbo charged engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 235 KW
  • Engine Prime Rating HP: 362 HP
  • Prime Power AMP Rating: 355 A
  • Fuel Usage (Field Gas): 37 MCF/DAY AT 50%, 52 MCF/DAY AT 75%
  • Fuel Usage (Propane): 354 GAL/DAY AT 50%, 525 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 200

The robust industrial 11L turbo charged engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 175 KW
  • Engine Prime Rating HP: 272 HP
  • Prime Power AMP Rating: 279 A
  • Fuel Usage (Field Gas): 28 MCF/DAY AT 50%, 40 MCF/DAY AT 75%
  • Fuel Usage (Propane): 270 GAL/DAY AT 50%, 399 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 150

The robust industrial 8L turbo charged engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 135 KW
  • Engine Prime Rating HP: 200 HP
  • Prime Power AMP Rating: 203 A
  • Fuel Usage (Field Gas): 21 MCF/DAY AT 50%, 30 MCF/DAY AT 75%
  • Fuel Usage (Propane): 190 GAL/DAY AT 50%, 266 GAL/DAY at 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 100

The robust industrial 8L naturally aspirated engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 80 KW
  • Engine Prime Rating HP: 160 HP
  • Prime Power AMP Rating: 106 A
  • Fuel Usage (Field Gas): 14 MCF/DAY AT 50%, 21 MCF/DAY AT 75%
  • Fuel Usage (Propane): 132 GAL/DAY AT 50%, 190 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 50

The robust industrial 8L naturally aspirated engine is U.S. EPA-certified and runs on natural gas or propane. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed.​Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 50 KW
  • Engine Prime Rating HP: 105 HP
  • Prime Power AMP Rating: 67 A
  • Fuel Usage (Field Gas): 12 MCF/DAY AT 50%, 16 MCF/DAY AT 75%
  • Fuel Usage (Propane): 126 GAL/DAY AT 50%, 166 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

NG 30

The robust industrial 3L naturally aspirated engine is U.S. EPA-certified and runs on natural gas. The generator is built upon a proven and reliable marine grade alternator that puts out 480 volt/3 phase/60 hertz power.

Trailer mounted to be portable and cost effective in any area where grid power is not available or reliable back-up power is needed. Exceptional engine performance achieved with an engine control unit that manages all critical functions including: Governor, Variable Ignition Timing, Air Fuel Ratio Control, Knock Suppression and Engine Protection.

Specifications

  • 24/7 Prime Power KW: 30 KW
  • Engine Prime Rating HP: 50 HP
  • Prime Power AMP Rating: 40 A
  • Fuel Usage (Field Gas): 6 MCF/DAY AT 50%, 8 MCF/DAY AT 75%
  • Fuel Usage (Propane): 82 GAL/DAY AT 50%, 113 GAL/DAY AT 75%
  • Remote Monitoring: Baseline Telematics Solution

The Baseline Process

Connect

We will discuss your pending power need.

Proposal

We’ll convert the discussion into a formal proposal for your review.

Approval

You review and approve.

Delivery

We commission the necessary equipment.